Air Isolation Super Flex


Super-flexible coaxial cables are used in narrow scenarios, requiring a certain degree of cable bending, and are generally used as patch cords

With special inner design to reduce the weight while not losing the performance



Construction
Inner Conductor CCA
Dielectric Material Foamed FEP (Star, air isolation)
Outer Conductor Corrugated Copper
Jacket FR PVC
Dimensions(Nominal) mm
Diameter Over InnerConductor 3.6
Diameter Over Dielectric 9.25
Diameter Over Outer Conductor 12.10
Diameter Over Jacket 13.4
Electrical Specification
Impedance 50 ± 1 Ω
Capacitance 80 ± 2 pF/m
Velocity 83 %
Dielectric Constant 2.1
VSWR ≤ 1.3
Screening Effectiveness > 120 dB
Operating Frequency

≤ 8.8 GHz

Peak Power Rating 16 KW
Insulation Resistance > 10000 MΩ.km
DC Resistance

—Inner Conductor

—Outer Conductor

≤ 2.9 Ω/km

≤ 5.1 Ω/km

Nominal Attenuation: dB/100m
30 MHz 1.73
80 MHz 2.86
150 MHz 4.02
450 MHz 7.27
900 MHz 10.75
960 MHz 11.30
1000 MHz 11.77
1500 MHz 14.34
1700 MHz 15.38
1800 MHz 15.97
1900 MHz 16.77
2000 MHz 17.14
2200 MHz 17.87
2300 MHz 18.40
2400 MHz 18.96
2500 MHz 19.42
3000 MHz 20.33
3300 MHz 23.16
3400 MHz 23.29
3500 MHz 23.82
3600 MHz 24.11
3800 MHz 24.79