| Construction | |
|---|---|
| Inner Conductor | CCA |
| Dielectric Material | Foamed FEP |
| Outer Conductor | Corrugated Copper |
| Jacket | Black PE |
| Dimensions(Nominal) | mm |
|---|---|
| Diameter Over InnerConductor | 1.9 |
| Diameter Over Dielectric | 4.5 |
| Diameter Over Outer Conductor | 6.4 |
| Diameter Over Jacket | 7.7 |
| Electrical Specification | |
|---|---|
| Impedance | 50 ± 1 Ω |
| Capacitance | 80 pF/m |
| Passive Intermodulation | ≤ -160 dBc |
| Velocity | 83 % |
| Dielectric Constant | 2.03 |
| Screening Effectiveness | > 120 dB |
| Operating Frequency |
≤ 18 GHz |
| Peak Power Rating | 3.94 KW |
| Dielectric Strength, short time | 80 𝑘𝑉/𝑚𝑚 |
| Insulation Resistance | > 1000 MΩ.km |
| DC Resistance
—Inner Conductor —Outer Conductor |
— ≤ 9.8 Ω/km ≤ 6.9 Ω/km |
| Attenuation
—1000 MHz |
34.34 |
| Mechanical Specification | |
|---|---|
| Minimum Bend Radius
—Operating —Installation |
—
min. 45 mm min. 25 mm |
| Tensile Strength | max. 500 N |
| Weight | — |
| Packaging | 500 m |
| Temperature | ℃ |
|---|---|
| Temperature Range
—Operating —Installation |
—
−70 ~+200 −70 ~+200 |