Construction | |
---|---|
Inner Conductor | CCA |
Dielectric Material | Foamed FEP |
Outer Conductor | Corrugated Copper |
Jacket | Black PE |
Dimensions(Nominal) | mm |
---|---|
Diameter Over InnerConductor | 1.9 |
Diameter Over Dielectric | 4.5 |
Diameter Over Outer Conductor | 6.4 |
Diameter Over Jacket | 7.7 |
Electrical Specification | |
---|---|
Impedance | 50 ± 1 Ω |
Capacitance | 80 pF/m |
Passive Intermodulation | ≤ -160 dBc |
Velocity | 83 % |
Dielectric Constant | 2.03 |
Screening Effectiveness | > 120 dB |
Operating Frequency |
≤ 18 GHz |
Peak Power Rating | 3.94 KW |
Dielectric Strength, short time | 80 𝑘𝑉/𝑚𝑚 |
Insulation Resistance | > 1000 MΩ.km |
DC Resistance
—Inner Conductor —Outer Conductor |
— ≤ 9.8 Ω/km ≤ 6.9 Ω/km |
Attenuation
—1000 MHz |
34.34 |
Mechanical Specification | |
---|---|
Minimum Bend Radius
—Operating —Installation |
—
min. 45 mm min. 25 mm |
Tensile Strength | max. 500 N |
Weight | — |
Packaging | 500 m |
Temperature | ℃ |
---|---|
Temperature Range
—Operating —Installation |
—
−70 ~+200 −70 ~+200 |